CHEMICAL / ENVIRONMENTAL RESISTANCE CHART |
 |
|
|
XR-5® 8130 Reinforced |
Standard |
Metric |
Base
Fabric Type
ASTM D3776 |
Polyester |
Base
Fabric Weight (nominal) ASTM D3776 |
6.5 oz/yd2 |
220 g/m2 |
Thickness
ASTM D751 |
30.0
mils min. |
0.76
mm min. |
Weight
ASTM D751 |
30.0
± 2 oz/yd2 |
1017
± 70 g/m2 |
Tear
Strength ASTM D4533, Trapezoid Tear |
35/35
lbf min. |
155/155
N min. |
Breaking
Yield Strength ASTM D751, Grab Tensile |
550/550
lbf min. |
2447/2447
N min. |
Low
Temperature
ASTM D2136, 4 hr - 1/8" mandrel |
Pass
@ -30 º F |
Pass
@ -35 º C |
Dimensional
Stability ASTM D1204, 212º F - 1 hr |
1.5%
max. each direction |
Adhesion
- Heat Sealed Seam
ASTM D751, Dielectric Weld |
35
lbf/2 in min. |
15
daN/5 cm min. |
Dead
Load - Seam Shear Strength ASTM D751 |
2
in seam, 4 hr, 1 in strip
210 lbf @ 70º F
105 lbf @ 160º F |
5
cm seam, 4 hr, 2.5 cm strip
934 N @ 21º C
467 N @ 70º C |
Bursting
Strength ASTM D751 Ball Tip |
650
lbf min.
800 lbf typical |
2892
N min.
3560 N typical |
Hydrostatic
Resistance
ASTM D751, Method A |
800
psi min. |
5.51
MPa min. |
Blocking
Resistance
ASTM D751 (180º F/82º C) |
#
2 Rating max. |
Adhesion
- Ply ASTM D413 |
15
lbf/in min.
or Film Tearing Bond |
13
daN/5 cm min.
or Film Tearing Bond |
Bonded
Seam Strength ASTM D751 as modified by NSF 54 |
550
lbf min. |
2447
N min. |
Abrasion
Resistance ASTM D3389 (H-18 Wheel, 1000 g load) |
2000
cycles (min.) before fabric exposure
50 mg/100 cycles max weight loss |
Weathering
Resistance
ASTM G23 (Carbon-Arc) |
8,000
hrs (min.) - No appreciable changes
or stiffening or cracking of coating |
Water
Absorption
ASTM D471, Section 12, 7 days |
0.025
kg/m2 max. @ 70º F/21º C
0.14 kg/m2 max. @ 212º F/100º C |
Wicking
Shelter-Rite® Procedure |
1/8
in max. |
0.3
cm max. |
Puncture
Resistance ASTM D4833 |
250
lbf min. |
1112
N min. |
Coefficient
of Thermal Expansion/Contraction
ASTM D696 |
8
x 10-6 in/in/ºF max. |
1.4
x 10-5 cm/cm/ºC max. |
We
believe this information is the best currently available on the
subject. We offer it as a suggestion in any appropriate
experimentation you may care to undertake. It is subject to
revision as additional knowledge and experience are gained. We
make no guarantee of results and assume no obligation or
liability whatsoever in connection with this information. In
case of conflict between standard and metric specifications,
standard shall apply. |